DC 180KW
ECOTEC
| Availability: | |
|---|---|
| Quantity: | |
| Power Suppply | 3P+N+PE |
| Rated Voltage | 400VAC±15%(50/60Hz) |
| THDi | ≤5% |
| Efficiency | ≥95% |
| Power Factor | ≥0.98 |
| Grid Frequency | 50Hz or 60Hz |
| Connector Type | CCS, CHAdeMO, GB/T |
| Output Voltage | 150-1000V |
| Maximum Output Current | 200A |
| Output Power Rating | 60KW-240KW |
| Output Voltage Accuracy | ≤0.5% |
| Output Current Accuracy | ≤±5% |
| HMI | 7-Inch touch screen |
| Charging Method | RFID Card |
| Cable Length | Cellular modem:GSM/4G (optional)LAN:10/100 Base-T Ethernet |
| Communication Protocol | OCPP 1.6J |
| Operating Noise Level | ≤60dBA |
| Ingress Protection(IP/IK rating) | IP54/IK08 |
| Power Meter | Accuracy Class 1 energy meter |
| Enclosure | Galvanized steel |
| Product Dimension | 700 x 550 x 1800mm(W x D x H) |
| Package Dimension | 950 x 720 x 1950mm(W x D x H) |
| Protection | Over Current,Under Voltage,Over Voltage,Short Circuit,Residual Current, Surge Protection,Over Temperature,Ground Protection |
| Certification Standard | EN/IEC 61851-1,EN/IEC 61851-23,EN/IEC 61851-24,EN/IEC62196-1,EN/IEC62196-3 |
| Operating Temperature | -35ºC to +50ºC |
| Storage Temperature | -40°C to +75°C |
| Maximum Installation Height | ≤2000m |
| Operating Humidity | 5%-95% RH |
| Power Suppply | 3P+N+PE |
| Rated Voltage | 400VAC±15%(50/60Hz) |
| THDi | ≤5% |
| Efficiency | ≥95% |
| Power Factor | ≥0.98 |
| Grid Frequency | 50Hz or 60Hz |
| Connector Type | CCS, CHAdeMO, GB/T |
| Output Voltage | 150-1000V |
| Maximum Output Current | 200A |
| Output Power Rating | 60KW-240KW |
| Output Voltage Accuracy | ≤0.5% |
| Output Current Accuracy | ≤±5% |
| HMI | 7-Inch touch screen |
| Charging Method | RFID Card |
| Cable Length | Cellular modem:GSM/4G (optional)LAN:10/100 Base-T Ethernet |
| Communication Protocol | OCPP 1.6J |
| Operating Noise Level | ≤60dBA |
| Ingress Protection(IP/IK rating) | IP54/IK08 |
| Power Meter | Accuracy Class 1 energy meter |
| Enclosure | Galvanized steel |
| Product Dimension | 700 x 550 x 1800mm(W x D x H) |
| Package Dimension | 950 x 720 x 1950mm(W x D x H) |
| Protection | Over Current,Under Voltage,Over Voltage,Short Circuit,Residual Current, Surge Protection,Over Temperature,Ground Protection |
| Certification Standard | EN/IEC 61851-1,EN/IEC 61851-23,EN/IEC 61851-24,EN/IEC62196-1,EN/IEC62196-3 |
| Operating Temperature | -35ºC to +50ºC |
| Storage Temperature | -40°C to +75°C |
| Maximum Installation Height | ≤2000m |
| Operating Humidity | 5%-95% RH |